A team member at LabGiant drafted this page. It was written from your own page at ibsc.ucsc.edu/microscopy-center.
It is not listed. It will not show up in search or browse, and only someone with the link can open it. Once you claim it, your facility takes its place on the UC Santa Cruz page.
Want changes, or want it taken down? Email [email protected].
UC Santa Cruz
Shared confocal and widefield microscopes, training and imaging help for life sciences at UC Santa Cruz.

The UCSC Life Sciences Microscopy Center is a shared use facility that provides imaging instrumentation for biomedical research. Our microscopes are in Sinsheimer Labs and the Biomedical Sciences Building, and we are supported by the UCSC Division of Physical and Biological Sciences and the California Institute for Quantitative Biosciences (QB3).
We serve the biological research community at UCSC and help you with every part of imaging, from experimental design to training on the shared microscopes to image analysis. We manage several widefield and confocal microscopes. Some are owned by the CIRM-funded UCSC Institute for the Biology of Stem Cells, and others belong to individual laboratories but are administered by the center.
Researchers inside and outside the life sciences are welcome. Investigators doing life sciences research get priority when reserving microscope time.
Start from your sample. We usually recommend starting with simpler, faster, less expensive widefield techniques, then moving to confocal if and when you need it.
1. Request training. Press Request training on the microscope you want, or request Microscope training under Services, about 7 to 10 days before you expect to start imaging, so you practice soon after. Tell us about your sample and the question you want to answer, with your faculty mentor's approval. Training and account setup are mandatory on every system before you use it on your own.
2. Safety, in the same request. Your training request carries our safety questions, so there is no separate form. Every user needs an approved Biological Use Authorization (BUA) on file, and the Zeiss live-cell widefield, the Zeiss AxioImager Z2 and the Zeiss 880 confocal also need documented BSL2 clearance. If you work in our BSL2 areas, we encourage the Biological Agents in Shared Facilities Awareness Training from the Campus Learning Center.
Once you are trained and have an active account, you receive a microscopy user ID and join the email group for each scope you use. If you have not used a microscope for more than 6 months, ask us for refresher training first.
3. Get your key. Request brass key access to Sinsheimer or key card access to Biomed, and list your PI as your supervisor, not our director. Keys to Sinsheimer 111 are picked up from the SOE Key office on the 3rd floor of Baskin Engineering.
4. Book your time. Reserve every session through the PBSci Equipment Reservation site with your CruzID, using the Campus VPN when you are off campus, and enter your microscopy user ID in the "Client's name or Status" field. Please cancel at least 24 hours ahead.
Coming from outside UCSC? Scope access for external users depends on schedule availability. Contact our director to learn more. Instruments bought on NIH instrumentation grants may also need approval from their oversight committee.

Our FY27 rates have three audiences:
Each microscope lists its hourly rate for all three. The Zeiss Axiozoom, the Zeiss live-cell widefield, the Zeiss AxioImager Z2, the Solamere spinning disk and both laser scanning confocals (Leica Stellaris and Zeiss 880) also offer a 24-hour rate, shown on each instrument.
Training on a recharge scope is a flat fee per person, per scope. UCSC users training on a scope that is not on recharge pay no training fee, but may be billed scope time for the length of the training session. External users training on a scope that is not on recharge are billed scope time for the length of the session.
Assisted imaging and on-scope assay development are add-ons, charged by the hour on top of the standard scope rate.
We bill instrument time by the time you are logged into your account on the instrument control computer, and we record technical assistance time by hand. The minimum is 1 hour per scope per month: a month with less than an hour of use on a scope is billed as 1 hour.
Our electron microscope is a user-sponsored resource supervised by Professor Melissa Jurica. Please send inquiries to our director, Ben Abrams.
For cryo-electron microscopy, contact Vitor Hugo Balasco Serrao at the Biomolecular Cryo-electron Microscopy Facility.
Every publication, poster and presentation that uses the center acknowledges us as:
"Technical support from Benjamin Abrams, UCSC Life Sciences Microscopy Center, RRID: SCR_021135."
Data from instruments bought on NIH instrumentation grants must also cite the grant, per federal policy, in the acknowledgements or methods:
Please let our director know when you cite the center so we can record the publication. We also share guidelines on when acknowledgement or co-authorship is warranted.
Request training on the microscope you need about 7 to 10 days before you plan to image. The request asks about your sample and our safety requirements in one go. Allow 2.5 to 4 hours for widefield training and 4 hours for confocal. Then request a Sinsheimer key or a Biomed key card, listing your PI as supervisor.
UC Santa Cruz
Sinsheimer Labs and Biomedical Sciences Building (office: Sinsheimer Labs, Room 150)
Santa Cruz, California
Get directions