    Arcturus XT laser capture microdissection system
    EquipmentDisponible

    Arcturus XT laser capture microdissection system

    Tarification

    Demander un devis

    Faculty of Medicine and Health Sciences
    Research Institute of the McGill University Health Centre
    McGill University

    The Arcturus XT provides ultimate flexibility in sample source and preparation

    The unique system combines Infrared (IR) laser capture and Ultraviolet (UV) laser cutting which can be used on any slide type and sample preparation. Choose from glass, glass membrane or framed membrane slides for contact or non-contact microdissection.

    Any specimen preparation may be used:

    • Thin or thick sections
    • Frozen or formalin-fixed tissues
    • Stained, fluorescently stained, or unstained sections
    • Hydrated or dehydrated specimens
    • Cell cultures

    Specifications

    Microscope: Nikon Eclipse® Ti-E microscope base. Standard microscope operation outside of LCM operating software

    Lasers: IR capture laser: solid-state (810 nm)

    Enhanced UV cutting laser: solid-state, diode-pumped Q-switched (345 nm) with adjustable laser current (0–100%) and pulse frequency (10–5,000 Hz)

    Illumination: High-intensity LED illumination system

    Objectives: 2x, 10x, 20x and 40x Nikon CFI60

    Intermediate magnification: 1.5x optical magnification

    Stage: Insert for three 75 mm x 25 mm slides, insert for large-format slides; Two positions, adjustable to 75 mm x 25 mm, 75 mm x 38 mm, 75 mm x 50 mm and stage insert for petri dish: 50 mm x 7 mm

    Contrast methods: Bright-field , phase contrast (PhL, Ph1, Ph2), differential interference contrast (DIC)

    Microdissection camera: 1024 x 768 1/3" color CCD with electronic shutter to 1/10,000s and on-chip integration to 30 seconds

    Histopathology Platform - RI-MUHC

    Histopathology Platform - RI-MUHC

    Faculty of Medicine and Health Sciences

    Laboratoire de recherche voué à faire avancer les connaissances scientifiques et l'innovation.

    FC

    Fazila Chouiali

    Histopathology Platform - RI-MUHC · McGill University
    EquipmentDisponible

    Arcturus XT laser capture microdissection system

    Tarification

    Demander un devis

    Faculty of Medicine and Health Sciences
    Research Institute of the McGill University Health Centre
    McGill University

    The Arcturus XT provides ultimate flexibility in sample source and preparation

    The unique system combines Infrared (IR) laser capture and Ultraviolet (UV) laser cutting which can be used on any slide type and sample preparation. Choose from glass, glass membrane or framed membrane slides for contact or non-contact microdissection.

    Any specimen preparation may be used:

    • Thin or thick sections
    • Frozen or formalin-fixed tissues
    • Stained, fluorescently stained, or unstained sections
    • Hydrated or dehydrated specimens
    • Cell cultures

    Specifications

    Microscope: Nikon Eclipse® Ti-E microscope base. Standard microscope operation outside of LCM operating software

    Lasers: IR capture laser: solid-state (810 nm)

    Enhanced UV cutting laser: solid-state, diode-pumped Q-switched (345 nm) with adjustable laser current (0–100%) and pulse frequency (10–5,000 Hz)

    Illumination: High-intensity LED illumination system

    Objectives: 2x, 10x, 20x and 40x Nikon CFI60

    Intermediate magnification: 1.5x optical magnification

    Stage: Insert for three 75 mm x 25 mm slides, insert for large-format slides; Two positions, adjustable to 75 mm x 25 mm, 75 mm x 38 mm, 75 mm x 50 mm and stage insert for petri dish: 50 mm x 7 mm

    Contrast methods: Bright-field , phase contrast (PhL, Ph1, Ph2), differential interference contrast (DIC)

    Microdissection camera: 1024 x 768 1/3" color CCD with electronic shutter to 1/10,000s and on-chip integration to 30 seconds

    Arcturus XT laser capture microdissection system
    Histopathology Platform - RI-MUHC

    Histopathology Platform - RI-MUHC

    Faculty of Medicine and Health Sciences

    Laboratoire de recherche voué à faire avancer les connaissances scientifiques et l'innovation.

    FC

    Fazila Chouiali

    Histopathology Platform - RI-MUHC · McGill University

    Ça pourrait aussi vous intéresser

    Découvrez d'autres ressources qui pourraient soutenir vos travaux

    Explore shared research infrastructure

    Histology in MontrealResearch infrastructure in MontrealCore facilities at McGill University
    LabGiant,

    Fonctionnalités

    Calendrier d'équipementProtocol CortexCRMRapports d'impact

    Explorer

    Index de rechercheTechniquesCommunautéForfaits

    En partenariat avec

    McGill UniversityConcordia UniversityUniversité de MontréalPolytechnique MontréalDobson Centre for EntrepreneurshipUniversity of Alberta
    © 2026 LabGiant
    EN|FR
    Politique de confidentialitéConditions d'utilisation